- Data sourceAMR meter data (OSOS)
- MethodMachine learning
- OutputFaulty meters identified
- NotificationReal-time alarm
Faults that protection equipment cannot see
Phase-to-earth faults at the low-voltage level often go undetected by existing protection equipment and, unnoticed for long periods, create serious safety risks on the network. NEAT addresses this with two complementary products: one analytics-based, one hardware-based.
Invisible to existing protection
Phase-to-earth faults often go undetected by the protection equipment on the network.
Unnoticed for long periods
A fault can stay on the network for a long time before the operator notices it.
Serious safety risk
An undetected fault creates serious safety risks on the network.
The NEAT family: Trace and Sense
The NEAT family approaches low-voltage faults in two complementary ways: NEAT-Trace follows the traces in existing meter data, while NEAT-Sense senses the fault directly in the field.
- InstallationTransformer LV panel
- MethodDirect field measurement
- OutputFaulty feeders identified
- NotificationMarked on GIS
Earth fault detection with NEAT-Sense
A single device installed at the substation detects earth faults on low-voltage feeders the moment they occur and reports the faulty feeder to SCADA and GIS.
- 01
Measure
At the substation, NEAT-Sense measures the residual current of each LV feeder.
- 02
Monitor
One device monitors every LV outgoing feeder individually.
- 03
Detect
Residual currents are tracked continuously; a fault is detected the moment it occurs.
- 04
Report to SCADA
The fault and its feeder are reported to SCADA via the RTU.
- 05
Locate on GIS
The faulty feeder is shown on GIS and operations crews are notified.
Detects the fault, shows where it is
NEAT-Trace picks up fault behaviour in meter data using machine learning; NEAT-Sense measures fault current directly in the field. Both report the result to the operator.
Machine-learning detection
NEAT-Trace uses a machine-learning algorithm to identify meters showing fault behaviour in AMR (OSOS) data.
Direct current measurement
NEAT-Sense detects the fault by measuring fault current directly with hardware in the transformer LV panel.
Location reported via GIS
The faulty feeder is reported to the operator via GIS, enabling a fast response.
Start with software, go deeper with hardware
Operators start with the data they already have; when higher sensitivity and clearer location information are needed, the hardware is deployed.
Complementary protection without extra hardware
Scans existing AMR data to detect faulty behaviour, with no hardware, integration or extra workforce required. It brings to light many faults that had gone unnoticed until then.
Higher sensitivity, clearer location
Detects the faulty feeder directly with hardware installed in transformer LV panels, taking low-voltage protection to its highest level.
Partner with NEAT
We work with electricity distribution companies and network operators. Let's explore together how NEAT can be deployed on your network.
info@novator.energy